Electrical Insulation Mat Class 4 – 36 kV Rated | BS EN 61111 Certified | Sold Per Metre
Class 4 Electrical Safety Mat - 36 kV Rated, 5 mm Rubber Insulation Mat
Protect your workforce with Electrical Safety Matting Class 4 (36 kV) — the highest-rated insulating matting conforming to BS EN 61111:2009.
Engineered for extreme voltage conditions, this mat provides a safe, slip-resistant, and durable floor covering in switchgear rooms, transformer areas, and power distribution zones.
The 5 mm thick construction ensures long-lasting insulation performance while maintaining flexibility for easy installation and trimming.
Each metre length is fully tested and batch-marked to guarantee compliance and traceability.
Whether used in power stations, electrical test bays, or industrial control rooms, this mat delivers unmatched protection against electrical shock and equipment faults.
Technical Specifications:
| Specification | Details |
|---|---|
| Product Code | ESM4-1.0M-5 |
| Standard | BS EN 61111:2009 / IEC 61111 |
| Class | 4 |
| Maximum Working Voltage | 36,000 V |
| Width | 1,000 mm (1m) |
| Thickness | 5 mm |
| Surface Finish | Fine fluted (top) / Cloth impression (underside) |
| Colour / Marking | Orange underside with class & voltage printed |
| Temperature Range | −20 °C to +70 °C |
| Chemical Resistance | Oil, acid, water resistant |
| Certification | Supplied with batch test certificate |
| Length Options | Sold per metre (cut to required length) |
Typical Applications
- High-Voltage Switchgear Rooms
- Power Generation Plants
- Electrical Test Laboratories
- Transformer Rooms / Substations
- Motor Control Centres (MCCs)
- Renewable Energy Facilities (Solar / Wind / Battery)
- Automation & Industrial Plants
- Training C
-
Constructed from high-quality elastomeric rubber, our Class 4 insulation mat is 5 mm thick and supplied in a standard width of 1 metre. The finely ribbed surface provides excellent slip resistance underfoot, while the cloth-impression backing improves grip on smooth floors.Each batch of Class 4 matting is electrically tested at 50 kV and certified for a safe working voltage of 36 kV. Orange colour markings indicate the Class 4 rating and printed voltage markers ensure traceability.
Typical applications include switchgear rooms, transformer bays, control panels, power stations, industrial test areas and renewable energy facilities. Use Class 4 matting wherever high-voltage protection and anti-slip footing are required.
For more information on selecting the right rubber matting for your facility, see our Rubber Matting Guide.
entres / Electrical Safety Education Labs
Browse More: View our full rubber matting range or read our rubber matting guide for expert advice.
📚 Learn More About This Product Type
Get expert advice on selection, installation, and maintenance:
- Industrial Rubber Flooring Guide - Complete buyer's guide
- HSE Workplace Flooring Guide
Browse All Guides →
Original: $298.40
-65%$298.40
$104.44Product Information
Product Information
Shipping & Returns
Shipping & Returns
Description
Class 4 Electrical Safety Mat - 36 kV Rated, 5 mm Rubber Insulation Mat
Protect your workforce with Electrical Safety Matting Class 4 (36 kV) — the highest-rated insulating matting conforming to BS EN 61111:2009.
Engineered for extreme voltage conditions, this mat provides a safe, slip-resistant, and durable floor covering in switchgear rooms, transformer areas, and power distribution zones.
The 5 mm thick construction ensures long-lasting insulation performance while maintaining flexibility for easy installation and trimming.
Each metre length is fully tested and batch-marked to guarantee compliance and traceability.
Whether used in power stations, electrical test bays, or industrial control rooms, this mat delivers unmatched protection against electrical shock and equipment faults.
Technical Specifications:
| Specification | Details |
|---|---|
| Product Code | ESM4-1.0M-5 |
| Standard | BS EN 61111:2009 / IEC 61111 |
| Class | 4 |
| Maximum Working Voltage | 36,000 V |
| Width | 1,000 mm (1m) |
| Thickness | 5 mm |
| Surface Finish | Fine fluted (top) / Cloth impression (underside) |
| Colour / Marking | Orange underside with class & voltage printed |
| Temperature Range | −20 °C to +70 °C |
| Chemical Resistance | Oil, acid, water resistant |
| Certification | Supplied with batch test certificate |
| Length Options | Sold per metre (cut to required length) |
Typical Applications
- High-Voltage Switchgear Rooms
- Power Generation Plants
- Electrical Test Laboratories
- Transformer Rooms / Substations
- Motor Control Centres (MCCs)
- Renewable Energy Facilities (Solar / Wind / Battery)
- Automation & Industrial Plants
- Training C
-
Constructed from high-quality elastomeric rubber, our Class 4 insulation mat is 5 mm thick and supplied in a standard width of 1 metre. The finely ribbed surface provides excellent slip resistance underfoot, while the cloth-impression backing improves grip on smooth floors.Each batch of Class 4 matting is electrically tested at 50 kV and certified for a safe working voltage of 36 kV. Orange colour markings indicate the Class 4 rating and printed voltage markers ensure traceability.
Typical applications include switchgear rooms, transformer bays, control panels, power stations, industrial test areas and renewable energy facilities. Use Class 4 matting wherever high-voltage protection and anti-slip footing are required.
For more information on selecting the right rubber matting for your facility, see our Rubber Matting Guide.
entres / Electrical Safety Education Labs
Browse More: View our full rubber matting range or read our rubber matting guide for expert advice.
📚 Learn More About This Product Type
Get expert advice on selection, installation, and maintenance:
- Industrial Rubber Flooring Guide - Complete buyer's guide
- HSE Workplace Flooring Guide
Browse All Guides →






